The auto level calculation formula is used to determine the Height of Instrument (HI) and Reduced Level (RL) from backsight (BS), intermediate sight (IS) and foresight (FS) readings. This article explains the HI and rise-and-fall methods, how to book a change point, and how to check arithmetic on a closed levelling run.
Basic Terms and Instruments
What is an Auto Level?
An auto level is a self-leveling optical instrument used for establishing or checking points in the same horizontal plane. It gives quick and reliable vertical control in construction and surveying.
Key terms you must know
- HI (Height of Instrument): The elevation of the instrument line of sight above the datum.
- RL (Reduced Level): The elevation of a point relative to a chosen datum.
- BS (Back Sight): A reading on a point of known RL used to calculate HI.
- FS (Fore Sight): A reading on a point whose RL you want to determine.
- Rise & Fall: Method that records the difference between consecutive readings to compute RLs.
Methods for Leveling Calculations
HI RL Method (Height of Instrument)
The HI RL method is simple and widely used. First determine HI using a benchmark of known RL. Then compute each unknown RL by subtracting the fore sight from the HI.
- Step 1: HI = RL (benchmark) + BS
- Step 2: For each point, RL = HI – FS
This method is straightforward for continuous runs. It minimizes arithmetic because HI is kept until you change instrument position.
Rise & Fall Method
Rise & Fall records the difference between successive staff readings. It is useful for checking arithmetic and handling long runs with multiple instrument setups.
- Step 1: Difference = previous staff reading − current staff reading.
- Step 2: If the difference is positive, the ground has risen; if it is negative, the ground has fallen. A larger staff reading means a lower ground point.
- Step 3: RL (new) = RL (previous) + Rise − Fall.
Auto Level Calculation Formula and Booking
Use the following compact formulas.
- HI = RLknown + BS
- RL = HI − staff reading (IS or FS); use FS at the change point before shifting the instrument.
- Rise = Previous reading – Current reading
- Fall = Current reading – Previous reading
Use IS readings for detail points observed from the current setup and an FS reading on the change point before moving the instrument. From the new setup, take a BS on that same change point to calculate the next HI.
Sample Reduced Level Booking (Worked Example)
Below is a small example showing how to book readings using the HI RL method. Bench mark RL = 100.000 m.
| Station / description | BS (m) | IS (m) | FS (m) | HI (m) | RL (m) |
|---|---|---|---|---|---|
| BM (known) | 1.500 | — | — | 101.500 | 100.000 |
| P1 | — | 0.850 | — | 101.500 | 100.650 |
| CP P2 (old setup: FS) | — | — | 1.230 | 101.500 | 100.270 |
| CP P2 (new setup: BS) | 2.000 | — | — | 102.270 | 100.270 |
Explanation: From BM RL = 100.000 m and BS = 1.500 m, HI = 101.500 m. P1 is an intermediate point, so RL = HI − IS = 100.650 m. P2 is the change point: the old setup takes FS = 1.230 m, giving RL = 100.270 m. After moving the instrument, take BS = 2.000 m on the same P2; the new HI is 102.270 m. The change-point RL remains 100.270 m.
Error Checking and Arithmetic Tests
Error checking keeps your leveling reliable. Two practical checks are commonly used.
1. Rise & Fall arithmetic check
For a completed run, Σ Rise − Σ Fall = Final RL − Initial RL. This checks the rise-and-fall arithmetic; it does not prove that the field observations are free from systematic or instrumental error.
2. BS and FS total check
For a closed run or a run between known benchmarks, Σ BS − Σ FS = Final RL − Initial RL. The table above is a partial example ending at a change point, so it cannot demonstrate a closing error check by itself. A full closure check requires the final foresight and the known closing RL.
Always re-check additions, column totals, and instrument readings. Small transcription mistakes are the most common source of error.
Practical Tips for Field Work
- Use short sight distances to reduce refraction and reading errors.
- Take multiple readings on critical points and average them.
- Record BS and FS immediately in a field book — never rely on memory.
- When shifting the instrument, always take a back sight on a point with known RL to compute the new HI.
- Perform an arithmetic check at the end of each run to spot mistakes early.
Frequently Asked Questions
What is the simplest formula for auto level calculations?
The simplest formula is RL = HI – FS. First compute HI using HI = RL(known) + BS, then subtract each fore sight from HI to get the reduced level.
When should I use HI RL method vs Rise & Fall?
Use the HI RL method for quick continuous runs and when you can maintain the same HI over several points. Use Rise & Fall for detailed checks, long runs with many instrument shifts, or when you want an additional arithmetic verification.
How do I perform the error check?
Use the arithmetic checks: sum of rises minus sum of falls must equal the change in RL between start and end. Also compare total BS and total FS against expected elevation changes. Any mismatch indicates an error to correct.
What must I record in the reduced level booking?
Record station names, BS, FS, computed HI, and RL. Note instrument setup locations and any remarks about sight quality or disturbances. Clear records make later checks and corrections easier.
Conclusion
Understanding the auto level calculation formula and the HI RL method makes leveling faster and more reliable. Whether you use the HI RL approach or rise & fall, consistent booking and simple arithmetic checks will catch errors early. Explore these methods on a few short field runs to build confidence and accuracy in your surveying work.